Amrita Vishwa Vidyapeetham uses a combination of conventional and alternative water sources to meet campus requirements. The reported sources include recycled water, rainwater harvesting, municipal supply, rivers, borewells, wells and stormwater. Water conservation measures include rainwater collection, groundwater recharge, monitoring of water use, and treatment and reuse of wastewater for suitable non-potable applications.

Source-wise Contribution to Total Water Consumption

The latest source-wise distribution supplied for this update identifies recycled water as the largest contributor (48%), followed by rainwater harvesting (15%). The remaining contribution is from municipal supply (11%), rivers (10%), borewells (6%), wells (5%) and stormwater (5%). Recycled water and rainwater harvesting together account for 63% of the reported source mix. These percentages describe source contribution; they should not be interpreted as the percentage of wastewater generated that is treated.

Water Extraction and Conservation Measures

Rainwater harvesting and recharge

Rainwater is harvested from building rooftops and other suitable catchment areas for non-potable use and groundwater recharge. The university has approximately 65,000 m² of rooftop catchment area, with an estimated annual rainwater collection potential of 60,000 m³. The infrastructure also includes 16 storage tanks with a combined capacity of 24,000 m³, 16 check dams and three remotely managed borewells. The estimated collection potential should not be interpreted as the actual annual volume of rainwater harvested.

Borewells and Wells

Borewells and open wells serve as sources of groundwater for campus water requirements. Their contribution to the overall water supply is monitored to support responsible groundwater utilisation.

Municipal and River Water

Municipal supply and river water contribute 11% and 10%, respectively, to the reported water-source mix. These sources supplement campus water requirements, with emphasis on sustainable sourcing and responsible water use to minimise impacts on natural water resources.

Stormwater management

Stormwater contributes 5% of the water-source mix. Rainwater runoff from campus areas is collected and directed towards recharge pits and storage structures, helping reduce surface runoff and facilitate groundwater recharge.

Treated and reused water

Treated wastewater is reused for non-potable applications, including landscape irrigation, toilet flushing and other campus utility purposes. Recycled water accounts for 48% of the reported total water consumption, highlighting its contribution to reducing freshwater demand. The reported reuse volume has been supported by flow-meter readings or campus-wise operational records.

Reported Annual Water-use Figures

The 2026 water-use records report drinking water consumption of 51,508 m³, utility water consumption of 83,259 m³ and treated/reused water of 104,958 m³. The total reported water-use volume is 239,725 m³, subject to verification that treated/reused water is not already included in utility-water consumption.

Drinking water consumption51,508
Utility water consumption83,259
Treated/reused water104,958
Combined arithmetic sum239,725

Data Quality and Reporting Notes

  • The source-wise percentages add to 100%; retain the underlying source-wise volume records, reporting period and calculation method as supporting evidence.
  • The previous webpage’s source percentages (municipal supply 25%, rivers 30% and groundwater 35%) do not match the latest distribution supplied and should be replaced.
  • Distinguish estimated rainwater-harvesting potential from actual harvested volume.
  • Report water extraction and supply separately from treated wastewater reuse to avoid double-counting.
  • Identify the campuses covered, reporting period, measurement method and estimation assumptions.
  • The daily peak/non-peak source values shown in the earlier webpage were not carried forward because the labels and figures require verification.
  • The monthly entries show 28,037 m³ for food-related drinking water against an annual total of 28,038 m³, and 104,959 m³ for treated/reused water against an annual total of 104,958 m³. Reconcile these 1 m³ differences against the original records.

Conclusion

The latest reported source distribution indicates that recycled water and rainwater harvesting together contribute 63% of the institutional water-source mix. The 2026 water-use records report 104,958 m³ of treated/reused water. Continued source-wise metering, campus-level reporting and reconciliation of monthly totals are necessary to substantiate these figures.