Back close

Parallel plate pressure sensors for gas pipeline intrusion detection applications

Publication Type : Conference Proceedings

Source : Proceedings of the 5th International Conference on Communication and Electronics Systems, ICCES

Campus : Amritapuri

School : School of Engineering

Department : Electronics and Communication

Year : 2020

Abstract : In this paper, a type of pressure sensor using a parallel plate capacitor which can be broadly applied in the technology development circle is designed. A rise of equivalent capacitance or reduction in dielectric value will cause negative real power measurement errors. Variation in capacitance can directly reflect in differential pressure, so by varying capacitance, the respective differential pressure can be obtained. The individuality of our designedstructure helped us to verify how pressure is varying concerning the varying dielectric value. Respective simulations are done using COMSOL Multiphysics software. Pipeline leakage and intrusion detection continue to be a tragic issue, the application of parallel plate sensor as a gas line intrusion detector can be successfully used to offer non-intrusive digital pipeline monitoring, by means of allowing operators to act rapidly in the occasion of a pipeline leakage or intrusion right into a plant area.

Cite this Research Publication : Girish, Greeshma, Paul, Christy, Nambiar, Nikhila P, Velayudhan, Aiswarya, Baby Sreeja S.D, Parallel plate pressure sensors for gas pipeline intrusion detection applications, Proceedings of the 5th International Conference on Communication and Electronics Systems, ICCES, 2020

Admissions Apply Now