Effect of twisted tape insert geometry on turbulent flow and heat transfer in a Twisted square duct

Publication Type : Journal Article

Publisher : Elsevier BV

Source : International Communications in Heat and Mass Transfer

Url : https://doi.org/10.1016/j.icheatmasstransfer.2026.111170

Keywords : Turbulent flow, Passive methods, Twisted tape, Twisted duct, Thermal performance, Heat exchanger

Campus : Chennai

School : School of Computing, School of Engineering

Department : Mechanical Engineering

Year : 2026

Abstract : The present study aims to numerically investigate the influence of geometrical parameters of twisted tape inserts, such as pitch ratio and length ratio, on fluid flow and heat transfer characteristics in a twisted square duct for turbulent flow conditions. The effects of these geometrical parameters on the Nusselt number, friction factor and overall thermal performance factor are examined. The study considers Reynolds numbers in the range 5000 to 25,000 under a constant wall temperature boundary condition. The pitch ratios of 0.25, 0.5, 0.75, 1, 1.25, 1.5 and 1.75 and length ratios of 0.2, 0.4, 0.6, 0.8 and 1 are considered for detailed analysis. Numerical simulations are carried out using ANSYS Fluent. The SST k-ω model is chosen in this study after analysing various turbulence models. The accuracy of the results is confirmed through comparison with existing experimental data. Findings show that the twisted tape significantly modifies the flow in twisted square ducts, enhances heat exchange and causes greater pressure drop relative to the twisted square duct without tape. The study reveals that the pitch ratio 1.75 case achieves the highest thermal performance among all pitch ratio cases, and the length ratio case 0.2 performs best among the varying length ratios. For different pitch ratio cases, when the Reynolds number is 15,000, the overall thermal performance factor peaks at 0.958 for a pitch ratio of 1.75. However, with a 0.25 pitch ratio and a Reynolds number of 25,000, it falls to 0.787. For different length ratio cases, when the Reynolds number is 5000 and 15,000, the overall thermal performance factor achieves 0.964, its highest value for a length ratio of 0.2. However, the minimum value observed is 0.79 at a Reynolds number of 25,000 when the length ratio is 1.

Cite this Research Publication : V.P. Chithra, Balaji Bakthavatchalam, V. Jayakumar, Reji Kumar Rajamony, Salem Algarni, Talal Alqahtani, Effect of twisted tape insert geometry on turbulent flow and heat transfer in a Twisted square duct, International Communications in Heat and Mass Transfer, Elsevier BV, 2026, https://doi.org/10.1016/j.icheatmasstransfer.2026.111170

Admissions Apply Now