Publication Type : Journal Article
Publisher : Elsevier BV
Source : International Communications in Heat and Mass Transfer
Url : https://doi.org/10.1016/j.icheatmasstransfer.2025.110005
Keywords : Heat exchanger, Thermal performance, Pitch ratio, Twisted tape, Swirl flow, Twisted square duct
Campus : Chennai
School : School of Computing, School of Engineering
Department : Mechanical Engineering
Year : 2026
Abstract : This research focuses on enhancing heat transfer by improving twisted tape design with a focus on minimising pressure drop, thereby achieving better thermal performance. The available literature mainly focuses on twisted tapes with uniform pitch within a twisted square duct. This indicates that a major research gap exists in analyzing the effects of non-uniform pitch twisted tape configurations on heat transfer and pressure drop within a twisted square duct. The primary objective is to investigate conjoined multi-tape systems forming compound tapes having varied pitch ratios within twisted square ducts. This is accomplished by examining situations with both increasing and decreasing pitch ratios, especially in laminar flow circumstances. The pitch ratio is gradually increased and decreased by 0.25, 0.5, and 0.75. ANSYS Fluent is used to carry out the simulation analysis. Validation against previously published experimental data confirms the accuracy of the obtained results. A uniform wall temperature boundary condition is used for the numerical analysis. Among the studied cases with an increasing pitch ratio, the 1:1.5:2 case provides higher thermal performance at Reynolds numbers 500 and 750, with values of 1.276 and 1.348. Whereas, the 1:2:3 case shows greater thermal performance at higher Reynolds numbers, reaching a peak of 1.364 at Reynolds number 1000 and values of 1.349 and 1.314 at Reynolds numbers 1250 and 1500, respectively. However, at Re = 500 for the 2:1.5:1 case, it falls to its lowest value of 1.18. Among the analysed cases with decreasing pitch ratios, the greatest thermal performance factor values were obtained for the 2:1.5:1 and 1:1:1 case compared to other cases. The thermal performance factor reaches a maximum of 1.23 when Re is 1000 in the 2:1.5:1 case. However, at Re = 500 for the 1:5:9 case, it falls to its lowest value of 1.02.
Cite this Research Publication : V.P. Chithra, V. Jayakumar, Balaji Bakthavatchalam, Sambhaji Kusekar, Reji Kumar Rajamony, Salem Algarni, Talal Alqahtani, Thermal performance of a twisted square duct with increasing and decreasing pitch compound twisted tape inserts: A numerical analysis, International Communications in Heat and Mass Transfer, Elsevier BV, 2026, https://doi.org/10.1016/j.icheatmasstransfer.2025.110005