Publication Type : Journal Article
Publisher : Springer Science and Business Media LLC
Source : Journal of Thermal Analysis and Calorimetry
Url : https://doi.org/10.1007/s10973-022-11286-8
Campus : Chennai
School : School of Engineering
Department : Mechanical Engineering
Year : 2022
Abstract : An experimental study has been done to evaluate the thermo-hydraulic performance of solar air heater having roughness element over the absorber plate in the form of a winglet type vortex generator. LCT technique is used to measure the Nusselt number over the absorber surface for Reynolds number (Re) of 3000–22,000 and roughness parameters such as relative roughness pitch (P/e) of 5–12, angle of attack (α) ranges of 30°–75° and relative roughness width (W/w) of 3–7. The Nusselt number and friction factor with this roughness are compared with smooth surface for similar flow condition. The maximum enhancement in Nusselt number and friction factor are obtained to be 2.91 and 2.85 times that of smooth surface, respectively. The optimum values of the roughness parameters are evaluated based on the thermo-hydraulic performance parameter criterion. The optimum roughness parameters obtained as the relative roughness pitch (P/e) of 8, angle of attack (α) of 60° and relative roughness width (W/w) of 5. The maximum value of the thermo-hydraulic performance parameter (THPP) is observed to be 2.95.
Cite this Research Publication : Amit Kumar, Apurba Layek, Thermo-hydraulic performance of solar air heater having winglet type roughness element, Journal of Thermal Analysis and Calorimetry, Springer Science and Business Media LLC, 2022, https://doi.org/10.1007/s10973-022-11286-8